Just about every member from our large efficiency income crew values customers' wants and enterprise communication for Tag Out Tags, Lockout Tagout Bags, Safety Padlock, We sincerely welcome both equally international and domestic company associates, and hope to work along with you during the in close proximity to foreseeable future!
China Wholesale Lock Out Tag Out Labels Manufacturers - Moulded Case Circuit Breaker Lockout CBL01-2 – Nanbowan Detail:

Moulded Case Circuit Breaker Lockout CBL01-2

a) Made from engineering plastic strengthened nylon PA.

b) Lock out different types of circuit breakers.

c) Fits on breaker toggles and can be tightened using screw driver.

Part NO. Description
CBL01-1 Size:45mm×25mm×10mm,max clamping 10mm,using screw driver
CBL01-2 Size:45mm×25mm×10mm,max clamping 10mm,without tools

 

The utility model relates to a circuit breaker safety lock device, in which a padlock fastener is arranged at the corresponding position of the face cover of the mounting case and the breaker opening button, and a padlock is arranged to lock the circuit breaker button through the fastener and the padlock. The utility model can effectively avoid serious personal casualties or major accidents of electrical line equipment, eliminate the hidden danger of safety and improve the safety of electricity use.

Power outage, tagout, tripartite confirmation

Before the maintenance, the maintenance of the power supply to confirm, multiple equipment common power supply, in the case of not affecting other equipment, you can carry out power off operation. If it interferes with some equipment, it can be temporarily disconnected after taking safety measures to carry out wire picking operation. If the power is controlled by a single device, the power can be cut off directly. No matter what kind of power supply must comply with: first disconnect the branch power supply, then disconnect the trunk power supply. Break the air circuit breaker first, then the disconnecting switch. After the completion of power outage operation, the sign prohibiting closing shall be hung in the operable part. The sign shall indicate the team, maintenance person, maintenance time content and contact information, and the safety officer shall be responsible for supervision.

Would it be all right to leave the lock/hang out

No way!

First of all, national, industry and enterprise standards have clear provisions on dangerous energy isolation and Lockout tagout:

Mechanical Safety Hazardous Energy Control Method Lockout Tagout

The standard specifies requirements for dangerous energy control that may cause injury to persons; Protection steps, techniques, designs, methods and performance indicators for controlling accidental release of hazardous energy to prevent injury to personnel. It is suitable for the design, manufacture, installation, construction, repair, adjustment, inspection, dredging, setting, trouble finding, testing, cleaning, disassembly, maintenance and maintenance of the machine in its whole life cycle.


Product detail pictures:

China Wholesale Lock Out Tag Out Labels Manufacturers - Moulded Case Circuit Breaker Lockout CBL01-2 – Nanbowan detail pictures

China Wholesale Lock Out Tag Out Labels Manufacturers - Moulded Case Circuit Breaker Lockout CBL01-2 – Nanbowan detail pictures

China Wholesale Lock Out Tag Out Labels Manufacturers - Moulded Case Circuit Breaker Lockout CBL01-2 – Nanbowan detail pictures

China Wholesale Lock Out Tag Out Labels Manufacturers - Moulded Case Circuit Breaker Lockout CBL01-2 – Nanbowan detail pictures

China Wholesale Lock Out Tag Out Labels Manufacturers - Moulded Case Circuit Breaker Lockout CBL01-2 – Nanbowan detail pictures

China Wholesale Lock Out Tag Out Labels Manufacturers - Moulded Case Circuit Breaker Lockout CBL01-2 – Nanbowan detail pictures


Related Product Guide:

We have the most advanced production equipment, experienced and qualified engineers and workers, recognized quality control systems and a friendly professional sales team pre/after-sales support for China Wholesale Lock Out Tag Out Labels Manufacturers - Moulded Case Circuit Breaker Lockout CBL01-2 – Nanbowan, The product will supply to all over the world, such as: Czech Republic, Madras, Mauritius, Our stock have valued 8 million dollar , you can find the competitive parts within short delivery time. Our company is not only your partner in business, but also our company is your assistant in the coming corporation.
  • The product manager is a very hot and professional person, we have a pleasant conversation, and finally we reached a consensus agreement.
    5 Stars By Carol from Bangladesh - 2017.02.18 15:54
    Factory equipment is advanced in the industry and the product is fine workmanship, moreover the price is very cheap, value for money!
    5 Stars By Liz from Ireland - 2018.12.11 14:13